Why is it important to also measure inverter production?

For owners of household-scale small power plants (HMKE), it is natural to monitor the feedback to the grid. This value shows how much of the produced energy the house does not use immediately, but sends into the public utility grid.


But is measuring only the feedback really enough?

The answer: no.
The feedback only shows the surplus, but tells nothing about the total production of your inverter. For example, it can happen that the house consumption is exactly equal to the instantaneous production — in this case the feedback is zero, but the production can still be significant.

A real example

We recently commissioned the ADA PZIOT-E02 device for a valued customer, equipped with native GreenHESS firmware. The installation is extremely simple:

  • Just set up the Wi-Fi network

  • In the admin interface, designate which phase the device connects to
    Then the ADA PZIOT-E02 automatically searches the network for the ADA P1 Meter and passes it the measured inverter performance data.

The ADA P1 Meter then ensures that these values — along with load import and export data — are uploaded in real-time to the okosvillanyora.hu cloud, where the user can monitor the system operation on a clear graphical interface.

Why is this useful?

  • Complete picture: You see all the produced energy, not just the part fed into the grid.

  • Consumption calculation: From import, export and inverter data, the house’s total instantaneous consumption can be accurately calculated.

  • Troubleshooting: If the inverter produces but there is no feedback and consumption is low, it may indicate a potential system fault.

  • Energy optimization: It is easier to decide when to turn on bigger consumers (washing machine, boiler, air conditioning) to maximize self-consumption.

Summary

Efficient operation of HMKE systems requires measuring not only the feedback but also the total inverter production. Using the ADA PZIOT-E02 and ADA P1 Meter pair, all necessary data are automatically, reliably and in real-time available.

PZIOT-E02 consumption meter – with native okosvillanyora.hu support

PZIOT-E02 consumption meter – with native okosvillanyora.hu support

2025.10.16.    1459

The Swiss army knife of phase measurement The PZIOT-E02 can provide great help in two situations: 1. If you don’t have an electricity meter with a P1 port In this case, the PZIOT-E02 functions as a…

More
Why is it important to also measure inverter production?

Why is it important to also measure inverter production?

2025.10.16.    1382

For owners of household-scale small power plants (HMKE), it is natural to monitor the feedback to the grid. This value shows how much of the produced energy the house does not use immediately, but sen…

More
More than a thousand households already use the Hungarian-developed ADA P1 Meter for more conscious energy use

More than a thousand households already use the Hungarian-developed ADA P1 Meter for more conscious energy use

2025.12.22.    1333

In recent times, it has become increasingly important for more Hungarian households not only to see their electricity bill but also to understand what is actually happening behind the scenes. The Debr…

More

Featured

ADA P1 Meter - smart meter for electricity meter +15 cm RJ12 data cable

ADA P1 Meter - smart meter for electricity meter +15 cm RJ12 data cable

The device collects nearly 40 data points (consumption, feedback, phase parameters, reactive energie..

18,900 Forint Ex Tax: 14,882 Forint

PZIOT-E02 – with native okosvillanyora.hu and hmke.app support

PZIOT-E02 – with native okosvillanyora.hu and hmke.app support

The PZIOT-E02 is a compact, DIN rail mountable consumption meter, capable of accurately measuring th..

12,900 Forint Ex Tax: 10,158 Forint

ADA P1 Meter Cable 35 cm

ADA P1 Meter Cable 35 cm

Straight connection 35 cm long data cable for ADA P1 Meter and compatible devices...

1,425 Forint Ex Tax: 1,122 Forint

ADA485 – RS485/Modbus & TCP/Modbus IoT bridge for HMKE and industrial devices

ADA485 – RS485/Modbus & TCP/Modbus IoT bridge for HMKE and industrial devices

Mikrosilver video provides additional information and a detailed setup guide: The ADA485 is..

24,892 Forint Ex Tax: 19,600 Forint