Periodic Calculation and Feed-in Tolerance

The okosvillanyora.hu system has been expanded with a new, practical feature that helps users who monitor the operation of their solar panel system based on annual billing. The new dashboard card consists of two separate parts, which together provide even more accurate data management and easier transparency.


1. Setting up periodic calculation
This function comes in handy when you reach the end of a billing cycle (for example, annual billing) and want to restart the measurement period. Here you can enter the import/export closing values listed on the current settlement invoice.

The system automatically deducts these values from the total energy statistics visible on the dashboard, so the displayed data will only relate to the next cycle.

This way you don’t have to calculate manually or restart data recording – everything automatically resets to a new time counting.

2. Setting feed-in tolerance
In the second part of the card, you can set on a monthly basis how much feed-in is allowed according to the service provider’s regulation. These values are tolerance ranges defined by the electricity supplier (e.g., MVM Hálózat), broken down by months, related to the nominal performance (kW) of your installed system.

Example: if the June tolerance value is 3 kWh/kW, and your system is 5 kW, then 15 kWh feed-in is allowed that month.

Based on the given values, the system automatically monitors the feed-in and indicates the result with color coding:

Green: the month’s feed-in is acceptable
Red: you have exceeded the monthly limit

These two settings together allow you to get a more accurate picture of your solar panel system’s current status and comply with billing and legal requirements – calculate more simply and precisely!


PZIOT-E02 consumption meter – with native okosvillanyora.hu support

PZIOT-E02 consumption meter – with native okosvillanyora.hu support

2025.10.16.    513

The Swiss army knife of phase measurement The PZIOT-E02 can provide great help in two situations: 1. If you don’t have an electricity meter with a P1 port In this case, the PZIOT-E02 functions as a…

More
Why is it important to also measure inverter production?

Why is it important to also measure inverter production?

2025.10.16.    430

For owners of household-scale small power plants (HMKE), it is natural to monitor the feedback to the grid. This value shows how much of the produced energy the house does not use immediately, but sen…

More
More than a thousand households already use the Hungarian-developed ADA P1 Meter for more conscious energy use

More than a thousand households already use the Hungarian-developed ADA P1 Meter for more conscious energy use

2025.12.22.    558

In recent times, it has become increasingly important for more Hungarian households not only to see their electricity bill but also to understand what is actually happening behind the scenes. The Debr…

More

Featured

ADA P1 Meter - smart meter for electricity meter +15 cm RJ12 data cable

ADA P1 Meter - smart meter for electricity meter +15 cm RJ12 data cable

The device collects nearly 40 data points (consumption, feedback, phase parameters, reactive energie..

15,900 Forint Ex Tax: 12,520 Forint

PZIOT-E02 – with native okosvillanyora.hu and hmke.app support

PZIOT-E02 – with native okosvillanyora.hu and hmke.app support

The PZIOT-E02 is a compact, DIN rail mountable consumption meter, capable of accurately measuring th..

9,900 Forint 12,899 Forint Ex Tax: 7,795 Forint

3pcs 1-phase PZIOT-E02 current meter – native okosvillanyora.hu support

3pcs 1-phase PZIOT-E02 current meter – native okosvillanyora.hu support

The package contains 3 pieces of PZIOT-E02 phase meters. The above price applies to 3 pcs.The PZIOT-..

24,900 Forint 29,900 Forint Ex Tax: 19,606 Forint

ADA P1 Bridge - Bridge for P1 reader +1m USB cable

ADA P1 Bridge - Bridge for P1 reader +1m USB cable

Compatible with any P1 meter that provides telegram/P1 data on the local network via HTTP GET (URL) ..

5,900 Forint Ex Tax: 4,646 Forint